Please see IRC Sec- 2. A comprehensive listing of references to foam sheathing in the model building codes, along with code adoption resources for your project location. Please note that the 2018 IRC has not been adopted by New York as of January 2018. Shear Walls & Sheathing Lateral Loads Quick-Card Based on the 2018 International Residential Code (IRC) This 6-page card quickly covers the construction essentials you need in loads and shear walls based on the new 2018 International Residential Code (IRC . Asphalt shingles shall be fastened to solidly sheathed decks. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. A fire-resistance rating of 1/2 hour shall be permitted in Mineral-surfaced roll roofing (R905.5) is allowed to a 1:12 slope. Details. The 10 square feet X 144 square inches per square foot = 1,440 square inches required. Fasteners for asphalt shingles shall be galvanized, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (2.67 mm)] shank with a minimum 3 / 8-inch-diameter (9.5 mm) head, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Roof will be fully vented. The IRC permits the installation of asphalt shingles on continuous sheathing with slopes as low as 2:12. In the 2015 IRC, load-bearing studs were limited to 10 feet in length. . A new Footnote j Requirements for braced wall lines, braced wall panel length and location, materials, fasteners, load path, and connections to roof and floor framing are among the topics that will be discussed. The City of Buffalo, Wyoming has adopted the 2018 IRC and follows the code requirements for roof assemblies as outlined in Chapter 9. R603.9.2.2 Wall Construction, Full-Height Sheathing in Lowest Story . (Ice and water shield) IS REQUIRED. Ice barriers. Where the roof sheathing is less than 3/4 thick, the . R905.2.2Slope.Asphaltshinglesshallbeused onlyonroof slopes of two units vertical in 12 units horizontal (2:12) or greater. A new high-capacity nail, the RSRS (Roof Sheathing Ring Shank) nail was added as an option for fastening roof sheathing. This full-color illustrative guide was developed to help building designers, builders, building officials and others using the code in the application of the . A new Footnote j Roof sheathing panel nominal thickness from 3/8 inch to 7/8 inch. Mineral-surfaced roll roofing (R905.5) is allowed to a 1:12 slope. (Roof Online Note: This is the rafter chapter, among other things. 4. Also covers wood panel (plywood, OSB) roof sheathing requirements.) Allowable spans for lumber used as roof sheathing shall conform to Table R803.1. All installations of new roof sheathing shall be inspected prior to the installation of any roofing materials. (Ice and water shield) IS REQUIRED. Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. The minimum requirement for roof sheathing is " thick. GoToWebinar App requirements: Windows 7 - 10 or Mac OSX Mavericks (10.9) - macOS Catalina (10.15) . All triple openings not exceeding 8 feet, the headers shall not be less than double 2x8, and not exceeding 10 feet, not less than double 2x10 supporting one floor or roof. 03. . Allowable spans for lumber used as roof sheathing shall conform to Table R803.1. 2018 IRC R905.1.2. Diagonal bracing and shear requirements per Sec. Date:_____ Job Address:_____ . See IRC Table R602.3(3) below for minimum wood structural panel span length, thickness, nail size, nail spacing, nail penetration, and stud spacing for the various wind exposure categories. SECTION R908: RE-ROOFING . 07-25-2012, 09:58 PM. Spaced lumber decking CoL Refer to the manufacturer's technical bulletin regarding requirements for existing deck boards. Before then, 6d common nails (.113 _ diam.x3. Where the existing roof has two or more applications of any type of roof covering all old material must be removed. Ice barriers. Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. structural roof sheathing to maintain the monthly average temperature of the underside of the structural roof sheathing above 45F (7C). My cabin trusses will be 24 oc and I will use either 1/2 or 5/8 osb sheathing and a standing seam metal roof. . A minimum of a 1" (25 mm) space shall be provided between the insulation and the roof sheathing and the location of the vent. Here's how it is specified in the Residential Edition of the Florida Building Code (FBC) and the International Residential Code (IRC). IRC Wall Bracing: A Guide Page 3 manner, offsets can affect braced wall panel location and, thus, the layout of openings for windows and doors in a series of braced wall lines on a given building side (elevation). Lateral bracing requirements shall be in accordance with Section R602.10. 5.2. Final Inspection: A final inspection is required for all roofing permits. 2015 International Residential Code February 2018 Use of Office of Education and Data Management (OEDM) training materials must be approved in writing by the State of Connecticut, Department of Administrative Services' Office of Communications. I do know that the 3/8" ply used to be rated 24/0, so it did meet code. R905.13 Thermoplastic single-ply roofing (Roof Online Note: This section covers PVC and TPO roofing.) 3. R908.3.1.1 Roof recover not allowed. It guides the participant through an in-depth review and analysis of the bracing requirements for wood-framed residential structures. IRC or IBC) focus on weather protection . 2006 INTERNATIONAL RESIDENTIAL CODE 291 ROOF ASSEMBLIES Roofing materials shall comply with 2018 International Building Code, Chapter 15 and 2018 International Residential Code, Chapter 9. Townhouses separated by a common as . So let's say the size of 1 opening you have provides 300 square inches of ventilation. Ice and Water Shield & Sheathing Requirements. Learners will be able to reference and interpret IRC provisions for truss design and roof framing and sheathing. 3. roof sheathing is less than 3/4 inch thick, the fasteners 2018 IRC Residential Re-Roof WHAT YOU NEED TO APPLY FOR A BUILDING PERMIT: . R905.10.1 Deck requirements. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Building Code 2018 of Kansas > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.8 Wood Shingles > 1507.8.1 Deck Requirements > 1507.8.1.1 Solid Sheathing Required. R602.10 27. The assembly shall be designed and constructed in accordance with the provisions of this chapter and Figures R606.11 (1), R606.11 (2) and R606.11(3) or in accordance with AWC NDS. For roof slopes from two units vertical in 12 units . sheathing Where Section R402.1.2 would require continuous insulation on exterior walls and structural sheathing covers 40 percent or less of the gross area of all exterior walls, the continuous insulation R-value shall bepermittedto be reduced by an amount necessary to result in a consistent total sheathing thickness, but not more than R-3, Section 2303 Minimum Standards and Quality. Most of the roofs I see with 3/8 are 3 tab, 20yr shingles so the weight probably fits. For instance, there are " panels rated for 24" rafter spacing. redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. This nail will become more widely used once the higher roof component and cladding forces from ASCE 7-16 are adopted. Water soaked or deteriorating decking must be replaced. sheathed options. Sheathing must be installed and fastened to the structure in accordance with the 2018 International Residential Code. (R905.2.2) Two layers of underlayment are required for roof slopes up to 4:12, per R905.1.1 What roof covering is acceptable if my slope is less the 2:12? . Both the 2018 IRC and 2018 IBC reference the 2018 WFCM for the design of wood structures. 2018 IRC R905.1.2. Ice and water barrier shall be provided from the lowest edges of roof to a point 24" in from the inside of the Jump to any section using the buttons. o Maximum Number of Roofing Layers: See 2012 IBC section 1510.3 or 2018 IBC section 1511.3 and 2012 IRC section 907.3 or 2018 IRC section R908.3 for requirements related to recovering vs. replacement. Asphalt shingles shall be fastened to solidly sheathed decks. The 2018 WFCM updates pre-engineered design provisions based on loads from ASCE 7-16 and design requirements from the 2018 NDS and 2015 SDPWS. . All installations of new roof sheathing shall be inspected prior to the installation of any roofing materials. When using a house wrap as a weather-resistant barrier (WRB), it must meet the 2018 International Building Codes requirements of a WRB for water-resistance and vapor permeability.It must also meet the 2018 International Residential Code (IRC) for water resistance (IRC R703.1.1).A superior house wrap is air- and moisture-resistant, permeable, and has a high UV-resistance and tear strength. Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks. The roof and ceiling assembly shall provide continuous ties across the structure to prevent roof thrust from being applied to the supporting walls. Sunroom: glazing >40% . R905.10 Metal roof panels. Spaced lumber decking CoL Refer to the manufacturer's technical bulletin regarding requirements for existing deck boards. Take 1,440 square inches and divide by 300 square inches = 4.8. Townhouse Separation All installations of new roof sheathing shall be inspected prior to the installation of any roofing materials. There is no upper limit on how thick your roof substrate is. shingle manufacturer's installation requirements. The International Residential Code (International Code Council, 2018) is a prescriptive code that applies to detached . Code Requirements for Drip Edge Drip edge must extend min. Garage front returns require 4', or at least 16" up to 10'with hold downs . R905.14 Sprayed polyurethane foam roofing. PERMIT REQUIREMENTS . Reference: 2018 IRC Table R503.2.1.1(1) About this chapter: Chapter 7 establishes the various types of materials, materials standards and methods of application permitted as interior and exterior wall coverings. International Residential Code 2018 (IRC 2018) . Sheathing must be installed and fastened to the structure in accordance with the 2018 International Residential Code. 3. TABLE R905.1.1(1) . A 1-hour fire rating for the wall separating the units, which is usually 5/8" Type-X drywall, is required. Need more help? for smooth shank cap nails. the 2018 International Residential Code (IRC) simplified wall bracing requirements. R908.3.1.1 Roof recover not allowed. One-hour-rated . Vertical leg of drip edge must extend more than 1/4" below sheathing Fascia Roof sheathing Subfascia Soffit Drip Edge and the IRC Roof drip edge is one of those products that just . Vent holes or strip cut in roof sheathing sized per the IRC code requirement or 1/600th of the ceiling area. If you are trying to determine the area in square inches, you can convert it by multiplying 144. R905.2.1 Sheathing Requirements. Document published by SAFEbuilt, Inc. 5.10.2019 3 of 3 There are no IRC requirements for spacing wood sheathing that I am aware of. Final Inspection: A final inspection is required for all roofing permits. 3/7/2018 2 2018 Connecticut State Building Code Introduction The 2018 CSBC Based on: 2015 ICC model codes IBC, IRC, IPC, IMC, IEBC, IECC 2017 NEC (NFPA 70) 2009 ICC/ANSI A117.1 Coming into effect: July 1, 2018 (projected) Apply to projects with primary permit application on or after that date Will consider approving modification requests to Sheathing R803. (R905.2.2) Two layers of underlayment are required for roof slopes up to 4:12, per R905.1.1 What roof covering is acceptable if my slope is less the 2:12? Final Inspection: A final inspection is required for all roofing permits. The 2020 Minnesota Residential Code adopts the 2018 International Residential Code (IRC). rial used for post-frame systems is 29-gauge steel roof sheathing. the 2018 and 2021 IRC Apply code requirements to design, plan submittals and/or inspection. roconnor (Robert J. OConnor) July 8, 2006, 5:20pm #3. Asphalt shingles shall be fastened to solidly sheathed decks. . Nonstructural wall and roof coverings. Design-based wind uplift criteria Wind uplift requirements shall be determined by using the design wind value of 115 mph within . If the nails penetrate the sheathing , but not the studs, the minimum plywood thickness that the IRC designates is 1/2 inch. All headers must be braced at the top; Roof Framing. R905.11 Modified bitumen roofing. requirements of table R 905.2.4.1 ROOFING MATERIALS & REQUIREMENTS Want to know more? contains requirements for habitable and nonhabitable sunrooms. Includes joist and rafter span tables. Actually panels marked "Sized for Spacing" simply mean . 2. . Please see IRC Sec- Evaporative cooling systems . 2" onto roof Drip edge must be fastened with 12-gauge roofing nails with 3/8 "-diameter heads every 12 o.c. Flashing at termination of roof covering over common wall. Energy Code Requirements IRC 2018 IBC 2018 IRC 2015 IBC 2015 IRC 2012 IBC 2012 Braced wall line(s) containing an alternate extend from the foundation to the underside of the roof sheathing. Townhouse with three or more attached dwellings will require eave . If the spacing between boards is too large, a structural panel . Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks. Where the existing roof has two or more applications of any type of roof covering, removal of all existing layers of roof covering is required. References are to the 2018 International Residential Code (sections are designated as R). Allowable span tables are provided that . Braced Wall Line Spacing (R602.10.1.1) - Braced wall line spacing establishes the amount of racking load that must be resisted by the two or more parallel braced wall lines in each . Water soaked or deteriorating decking must be replaced. Wall bracing is a common source of confusion and misapplication although it is of critical importance when designing, performing plan review, building or inspecting a structure. The Owner or Contractor is required to obtain a Fast-Track Roofing Permit for all roof replacements. Fire-resistance classification requirements are based on the type of construction and the building use group. Chapter 3 of the IRC also contains the requirements for when and where fire-resistant construction is needed. Table 1. For roof sheathing 3/8 of an inch to 1 inch thick, the use of 2 1/2-inch-long 8d common nails installed 6 inches on center at supported panel edges and 12 inches on center at intermediate supports is a minimum requirement. Structural roof and wall sheathing from each unit may fasten to the . up to roof sheathing, or ceiling and walls supporting ceiling must be rated. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Water soaked or deteriorating decking must be replaced. 2018 IRC Update Page 6 Chapter 6: Wall Construction, Continued Code Section Section Title Description of Change 2018 2015 Modification R602.10.4.1 R602.10.4.1 Mixing bracing methods Mixing of continuous sheathing methods with an intermittent alternate bracing method is clarified. requirements. 2018 International Residential Code Amendments 3. The 2018 International Residential Code (IRC) adds a new option for the use of fiberglass and mineral . Asphalt shingles shall be fastened to solidly sheathed decks. RESIDENTIAL RE-ROOFING. Metal roof panel roof coverings shall be applied to solid or spaced . Spaced lumber sheathing is not allowed in Seismic Design Category D2. Permits and Plans R905.12 Thermoset single-ply roofing (Roof Online Note: This section covers EPDM roofing.) Over roof drains or gutters or downspouts that connect to drainage pipes, provided they terminate at or above grade in an area capable of absorbing the condensate flow without surface drainage. Please verify the following before calling for roof sheathing, shear wall, or braced wall panel inspection. Where the roof sheathing is . R905.9 Built-up roofs. Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of Sections R905.7 and R905.8. Residential Roof Sheathing and Shear Walls or Braced Wall Panels This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. 11 Sunrooms (R301.2.1.1.1) 2015 IRC requires sunrooms to comply with AAMA/NPEA/NSA 2100- Building Department 2018 IRC Plan Review Check Sheet . 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. It must extend from foundation to underside of roof sheathing. Enclosed attics and enclosedrafter spaces formed where cei lings are applied directly tothe underside of roof rafters shall have cross ventilation foreach separate space by ventilating openings protectedagainst This is similar to the requirements in the 2015 IECC and IRC, but the user should recognize that both standards were updated to 2017 editions in the 2018 IECC. 2021 International Residential Code . The International Residential Code specifies 3/8-inch plywood for sheathing walls with a standard stud spacing of 16 inches, if the siding is nailed to the studs through the sheathing. Minimum requirements for roof assemblies are found in Chapter 15 of the IBC, Chapter 9 of the IRC, and Chapter 7 of the IEBC. This chapter covers wood floor framing, wood floors on the ground, cold-formed steel floor framing and concrete slabs on the ground. Exceptions: 1. About this chapter: Chapter 5 provides the requirements for the design and construction of floor systems that will be capable of supporting minimum required design loads. 2x solid roof joists have cross-ventilation R806.1 Over-framing roof rafters, ridge beam & king posts installed per plan details Lower roof deck continuous under all over-framing or 2x top chord bracing installed Provide for minimum 20"x30" finished access opening where attic height >30" R807, M1305.1.3 For calculation purposes, an interior air temperature of 68F (20C) is assumed and the exterior air temperature is assumed to be the monthly average outside air temperature of the three coldest months. CONTINUE WITH CODE REQ'S If a request is made to install new solid sheathing over the existing spaced sheathing- the sheathing must be nailed in accordance with nailing schedule found in the 2018 IRC Crickets are required for all chimneys and saddles (ridge side) 30" or wider per 903.2.2. provided in Section R302.2. Where the existing roof has two or more applications of any type of roof covering. Townhouse Separation (R302.2 CT Amd) Uses 2018 IRC language to favor (2) 1-hour fire-resistance rated walls Common walls rated 2 hours w/o fire sprinklers is an alternative . General Re-Roof Requirements . Ice and water barrier is required at all eave edges of heated and/or insulated structures. common wall framing. longevity of your new roof: Roof Sheathing Preparation (for com-plete tear offs): . Fasteners: Fasteners for asphalt shingles shall be galvanized steel, aluminum or copper roofing nails, minimum 12-guage shank with a min 3/8 diameter head, complying with ASTM F 1667, of length to penetrate through the roofing materials and not less than 3/4 into the roof sheathing. R905.2.1 Sheathing requirements. Interior coverings include interior plaster, gypsum board, ceramic tile, wood veneer paneling, hardboard paneling, wood shakes and wood shingles. Gerry. Don, that might be a good angle. 2021 INTERNATIONAL RESIDENTIAL CODE SECTION R806 ROOF VENTILATION R806.1 Ventilation required. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. Section R802.11.1 Uplift resistance. The system must: 02. Revised 7/14/20 . Residential Code (IRC) wood structural panel roof sheathing nail size by inclusion of 8d common nail and adds the Roof Sheathing Ring Shank Nail (RSRS-01) to Table 2304.10.1 as options for roof sheath - ing attachment [S272-16] ects the 10d common nail length, Corr removes redundant requirements for stud nailing, creates consistency with the . The pass/fail criterion for swinging doors remains at 0.5 cfm per square foot. For wood structural panel roof sheathing attached to gable end roof framing and to intermediate supports within 48 inches of roof edges and ridges, . and the roof sheathing. 2018 International Residential Code (IRC) . R803.1 Lumber sheathing. R905.2.1 Sheathing requirements. ROOFING REQUIREMENTS 2018 IRC . The IRC permits the installation of asphalt shingles on continuous sheathing with slopes as low as 2:12. The pass/fail criterion for windows, skylights and sliding glass doors remains at 0.3 cfm per square foot. . Roofing materials must . 2. Sheathing mus t be installed and fastened to the structure in accordance with the 2018 International Residential Code. R905.2.1 Sheathing requirements. _) were the minimum allowed, but 8d box or 8d common nails were often used Thickness allowed depends on how far apart rafters or trusses are spaced and the rating of your roof decking. roof sheathing, skylights, change of roof pitch, addition or relocation of mechanical units, or installation of heavier materials than were previously installed. 2018 International Residential Code: Fundamental Provisions, Concepts, and Existing Buildings. 2 RESIDENTIAL ROOFING GUIDE 2018 IRC. Shingles must be self sealed at the time . See footnotes in Table R302.1(1). Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than 3 / 4 inch (19 mm) into the roof sheathing. Requirements for Wood Structural Panel Wall Sheathing Used to Resist Wind Pressures; . However, it is considered good practice to leave a 1/8" gap between sheets, and that is also "recommended" by APA but it is not required. No unprotected . The rim board header detail that was . Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks.